--
Feature:
1.The external LCD module laser PSU uses ordinary H/L/P/G/IN/5V as input control signal interface. And it uses yellow aluminum upper cover and base, galvanized sheet shell and two fans for heat dissipation of internal electronic components.
2.The laser power's emission control is simple, the 80W laser PSU can select 0-5V or PWM control signal for laser
3.This internet cable port laser PSU has stable working performance: Each external LCD module laser PSU has been much more testing procedures and under full load high temperature (52~55 degrees celsius) 24 hours of aging, which ensure the stability of each 80W laser PSU.
4. External LCD screen can display the 80W laser PSU’s output current and CO2 laser PSU's working status and fault code.Output current can be adjusted by this LCD screen's potentiometer
5.The internet cable port laser PSU has good protection feature: The 80W laser PSU has open circuit protection to make the external LCD screen module laser PSU works for short time in the open state, so as to make it avoid the laser tube damaged.
6.This internet cable port laser PSU has easy control: The CO2 laser PSU uses high or low level for control. The use of TTL-level control can realize start and stop quickly. At the same time the 80W laser PSU adds a protection switch, testing is made by external water and ventilation.
Specification
lnput | Input voltage | AC220V±10% (AC110V specified while order) | ||
AC frequency | 47~440HZ | |||
Maximum input power | 750W | |||
Maximum input current | 3.4A | |||
Output | Maximum output voltage | 32KV | ||
Maximum output current | 33mA (depending on the laser tubes of different manufacturers) | |||
Efficiency | More than 90% (Full load) | |||
Response speed | Not more than 1ms | |||
Control lnterace | TTL multilevel switching control,effective level can be high and low selection (see control wining diagram) | |||
Insulation | lnput-output | AC 1500V 1 minutes not more than 10mA | ||
lnput-shell | AC 1500V 1 minutes not more than10mA | |||
Output-shell | Connection | |||
Open Circuit Protection | Can be short circuit (requires a good grounding shell,while avoiding the positive electrode and the shell between the arc) | |||
Environmental Requested | Working temperature | -10℃~50℃ | ||
Storage of temperature | -20℃~75℃ | |||
Relative Humidity | Maximum 85%RH (non-condensing) | |||
Altitude | 100,000 feet of work 200,000 feet of storage,dose not work | |||
Cooling methods | Forced air cooling (fan cooling) | |||
Dimensions (LxWxH) | 283mmx178mmx106mm |